Fujitsu-siemens-computers SPARC Enterprise M8000 Manual de usuario Pagina 129

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 162
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 128
Appendix A Message Meaning and Handling A-13
[Explanation] Detected lack of memory resource.
[Remedy] Check the size of memory, detach the board and attach again. If the
problem still exists, please contact customer service.
[Output] Console and Standard Output
Internal error: dr.c #
[Explanation] There may be inconsistency in the system.
[Remedy] Please contact customer service.
[Output] Console and Standard Output
Internal error: dr_mem.c #
[Explanation] There may be inconsistency in the system.
[Remedy] Please contact customer service.
[Output] Console and Standard Output
Invalid argument: dr@0:SBX::memory
[Explanation] The memory board X is currently involved in other DR operation
and cannot be detached.
[Remedy] Repeat the action. If this error message appears again, please contact
customer service.
[Output] Console and Standard Output
Invalid board number: X
[Explanation] Invalid board number.
[Remedy] Check the board number and repeat the action. If this error message
appears again, please contact customer service.
[Output] Console and Standard Output
Kernel cage is disabled:
[Explanation] The kernel cage memory feature is disabled.
[Remedy] Ensure /etc/system is edited to enable kernel cage memory.
[Output] Console and Standard Output
Memory operation failed: dr@0:SBX::memory
[Explanation] There may be inconsistency in the system.
[Remedy] Please contact customer service.
[Output] Console and Standard Output
Vista de pagina 128
1 2 ... 124 125 126 127 128 129 130 131 132 133 134 ... 161 162

Comentarios a estos manuales

Sin comentarios